Industrial andcommercial ESS 60/100/215kWh

$6999.00 $6999
sales
Quantity
-+
DHL,UPS,FedEX
Description
ESS-60kWh
Product Model GIB-60KP
Battery Cabinet Parameters
Battery Cabinet Dimensions 1068x1035x1850mm
Weight 950kg
Nominal voltage 614.4V
Standard charge rate 0.5C/25°C
Maximum continuous discharge rate 1C/25°C
Energy 61.44KWh
Operating voltage range 537.6V-691.2V
Maximum Cell Charge Voltage 3.6V
Minimum cell discharge voltage 2.8V
Battery string Parameters
Battery pack size 420X155X570mm
Nominal capacity 100Ah
Nominal voltage 51.2V
Standard charge rate 0.5C/25°C
Maximum continuous charge rate 1C/25°C
Energy 5.12KWh
Operating voltage range 44.8V-57.6V
Maximum Cell Charge Voltage 3.6V
Minimum cell discharge voltage 2.8
Insulation performance □1000Ω/V
Single cluster configuration information
Battery pack 51.2V 100Ah (12PCS)
Slave BMU 16S (12PCS)
High Voltage control box BCU (1PCS)
Equipment cabinet 1068x1035x1850mm (1PCS)
Fire protection system FGS-XR1000E (1 SET)
Connect cables and communication cables (1 SET)
PCS Energy Storage Converter Technical Data Sheet (PWS1-30K)
Ac parameters
Ac access mode three-phase four-wire
Rated AC power 30KVA
Ac overload capability 33kVA
Allowable grid voltage 230/400(-15%~15%)Vac
Allowable grid frequency 50/60(-2.5-2.5)Hz
DC side parameters
Maximum DC power 33kW
Dc voltage range 320V~850V
Maximum DC current 100A
Voltage regulation accuracy □□1%



 
ESS-100kVVh
Product Model GIB-100KP
Battery Cabinet Parameters
Battery Cabinet Dimensions 1450x1200x2050mm
Weight 1500kg
Nominal voltage 358.4V
Standard charge rate 0.5C/25°C
Maximum continuous discharge rate 1C/25°C
Energy 100.3KWh
Operating voltage range 313.6V-403.2V
Maximum Cell Charge Voltage 3.6V
Minimum cell discharge voltage 2.8V
Battery string Parameters
Battery pack size 779X420X230mm
Nominal capacity 280Ah
Nominal voltage 51.2V
Standard charge rate 0.5C/25°C
Maximum continuous charge rate 1C/25°C
Energy 14.336KWh
Operating voltage range 44.8V-57.6V
Maximum Cell Charge Voltage 3.6V
Minimum cell discharge voltage 2.8
Insulation performance □1000Ω/V
Single cluster configuration information
Battery pack 51.2V 280Ah (7PCS)
Slave BMU 16S (7PCS)
High Voltage control box BCU (1PCS)
Equipment cabinet 1450x1200x2050mm (1PCS)
Fire protection system FGS-XR1000E (1 SET)
Connect cables and communication cables (1 SET)
PCS Energy Storage Converter Technical Data Sheet (PWS1-50K)
Ac parameters
Ac access mode three-phase four-wire
Rated AC power 50KVA
Ac overload capability 55kVA
Allowable grid voltage 230/400(-15%~15%)Vac
Allowable grid frequency 50/60(-2.5-2.5)Hz
DC side parameters
Maximum DC power 55kW
Dc voltage range 320V~850V
Maximum DC current 160A
Voltage regulation accuracy □□1%


 
ESS-215kWh
Product Model GIC-215KPF GIC-215KNY
Battery Cabinet Parameters
Battery Cabinet Dimensions 1800x2300x1200mm 1250x2050x1350mm
Weight 2800kg 2900kg
Energy 215.04KWh 220.5KWh
Standard charge rate 0.5C/25°C 0.5C/25°C
Maximum continuous discharge rate 1C/25°C 1C/25°C
Cooling Modes air-cooling liquid-cooling
Operating voltage range 672V-864V 650V-936V
Maximum Cell Charge Voltage 3.6V 3.6V
Minimum cell discharge voltage 2.8V 2.5V
Battery string Parameters
Battery pack size 779X420X230mm 1175X660X242mm
Nominal capacity 280Ah 265Ah
Nominal voltage 51.2V 166.4V
Standard charge rate 0.5C/25°C 0.5C/25°C
Maximum continuous charge rate 1C/25°C 1C/25°C
Energy 14.336KWh 44.1KWh
Operating voltage range 44.8V-57.6V 130V-189.8V
Maximum Cell Charge Voltage 3.6V 3.65V
Minimum cell discharge voltage 2.8 2.5
Insulation performance □1000Ω/V □1000Ω/V
Single cluster configuration information
Battery pack 51.2V 280Ah (15PCS) 166.4V 265Ah (5PCS)
Slave BMU 16S (15PCS) 52S (5PCS)
High Voltage control box BCU (1PCS) BCU (1PCS)
Equipment cabinet 1800x2300x1200mm (1PCS) 1250x2050x1350mm (1PCS)
Fire protection system FGS-XR1000E (1 SET)
Connect cables and communication cables (1 SET)
PCS Energy Storage Converter Technical Data Sheet (PWS1-100K)
Ac parameters
Ac access mode three-phase four-wire three-phase four-wire
Rated AC power 100KVA 100KVA
Ac overload capability 110kVA 110kVA
Allowable grid voltage 230/400(-15%~15%)Vac 230/400(-15%~15%)Vac
Allowable grid frequency 50/60(-2.5-2.5)Hz 50/60(-2.5-2.5)Hz
DC side parameters
Maximum DC power 110kW 110kW
Dc voltage range 500V~950V 500V~950V
Maximum DC current 180A 180A
Voltage regulation accuracy □□1% □□1%